forLoCo read
read voltage at IS: 75 ± 20 % mVpp
inductance @ 1 kHz / 50 mV: 1350 mH ± 20 % DC
resistance:1780 Ω ± 20 %
gap length:0.05 mm
Measurement Conditions
recording medium: 3M 777GP
relative velocity: 19 cm/s
recording density: 210 FRPI
equivalent write frequency: 0.788 kHz
Application | MICR (read) |
Number of Tracks | 3 |
Surface Treatment | no |